DC/DC converters by EDR |
iUPSThe first 1.5W, 3W and 6W iUPS-DC/DC with isolated converters and internal Lithium-Ion batteries for the most demanding bio-medical and industrial applications The EDR/Vsholding’ iUPS-DC/DC converter provides a complete solution for bio-medical and industrial needs for protecting vital data gathering in cases of power failure and surge protection. The iUPS is designed to deliver up to 1.5W, 3W or 6W at all industrial standard output voltages to any peripheral device. It is a general purpose wide input DC/DC converter with remote control. An internal precision fast charger with temperature compensation maintains the internal Lithium-Ion batteries fully charged to provide a truly uninterrupted and regulated DC output(s) despite large input voltage and load variations. Input and output protection is provided by electronic current limiting. STANDARD RATINGS for iUPS-X YY W
· For proper charging of the internal battery the input voltage should be anywhere from 8 VDC to 16 VDC. The DC/DC converter will continue to function until the voltage drops below 4.5VDC. Simple external circuitry can be added to enable an internal battery to provide power to the DC/DC converter only if the input voltage drops below 4.5V. Ordering Example: P/N iUPS-2153 (EDR82140) This is a +/-12 VDC, 3W iUPS-DC/DC converter with an internal Lithium-Ion battery.
Simplified block-diagram of the iUPS
The iUPS represents the unique designed which allows providing of up to 6W uninterrupted, isolated power either from the internal Lithium-Ion battery or an external power supply. The charge uses a flexible pulse-width modulation, two-phase fast-charging algorithm to control voltage and current during charging. The switch-mode design minimizes power dissipation. The charger starts a full charging cycle when at least 9.5VDC is applied. Thou an internal voltage converter (DC/DC converter) start delivering an output voltage since 4.5 VDC. The enable terminal must connect to the GND (Power Supply return) to enable the internal battery supply power to the converter. The batter starts providing power to converter when the enable grounded and the power supply voltage is a lower than the battery’s voltage. To request addition information about this product or another OEM product by EDR please fill out the Product Request Form or call us at 1-800-336.1.EDR |
|||||||||||||||||||||||||